TM411-8RM90/115
Thermometer, Hygienic High End iTHERM TM411
TM411-AA1AB1B1DB2D1A70Q1A000A3A1C42CR3A1A1+DC
010: Approval: AA: Non-hazardous area
020: Thermowell: 1: With weld-in adapter
030: Material Wetted Parts: A: 316L
040: Process Connection Type: B1: Weld-in adapter
050: Process Connection Size: B1: Weld-in adapter cylindrical D12.7mm, 3-A, EHEDG, ASME BPE
060: Thermowell External Diameter D1: D: 12.7 mm
070: Tip Shape; External Diam. D2; Length Re: B2: Reduced; 5.3 mm; 20 mm
080: Surface Wetted Parts: D1: Ra <= 0.76 (D1=12.7 mm)
090: Immersion Length U: A70: 90 mm
100: Neck: Q1: iTHERM QuickNeck neck separable - quick release
110: Neck Length E: A0: Not needed
120: Lagging Length T: 00: Predefined (not selectable)
130: Sensor Type; Measuring Range: A3: 1xPt100 TF, QuickSens fast response; -50...+200oC
140: Insert Design; Diam. d; Sheath Material: A1: 4-wire isolated wires; 3mm; 316L
150: Accuracy acc. IEC60751: C4: Class AA (QuickSens, 3mm)
160: Electrical Connection: 2C: 4-20mA, 1-channel TMT71, hea